Polymer Hose Distribution Catalogue 4402
Technical handbook
The correct method to fit ISO 6162-1 flange
The correct method to fit ISO 6162-1 flange
• Make sure sealing surfaces are free of burrs, nicks, scratches or any contamination • Lubricate the O-ring
• Position flange and clamp halves • Place lock washers on bolts and bolt through clamp halves
• Hand tighten bolts • Torque bolts in
• Tighten bolts according to chart
Technical handbook
diagonal sequence in small increments to the appropriate torque level listed in chart
with system fluid or compatible lubricant
Spanner torque values
ISO 6162-1 flange
Assembly torque Tolerances: max. 10%; min. 0%
Assembly torque Tolerances: max. 10%; min. 0%
G Thread
G Thread
DN
Inch
Size
metric
Nm
UNC (Inch)
Nm
13 19 25 32 38 51 64 76 89
1/2 3/4
-8
M8x1.25 M10x1.5 M10x1.5 M10x1.5 M12x1.75 M12x1.75 M12x1.75
24 50 50 50 92 92 92
5/16-18 3/8-16 3/8-16 7/16-14 1/2-13 1/2-13 1/2-13 5/8-11 5/8-11 5/8-11 5/8-11
24 43 43 70
-12 -16 -20 -24 -32 -40 -48 -56 -64 -80
1
1-1/4 1-1/2
105 105 105 210 210 210 210
2
2-1/2
3
M16x2 M16x2 M16x2 M16x2
210 210 210 210
3-1/2
102 127
4 5
ISO 6162-1 flange 5000 psi
Assembly torque Tolerances: max. 10%; min. 0%
Assembly torque Tolerances: max. 10%; min. 0%
G Thread
G Thread
DN
Inch
Size
metric
Nm
UNC (Inch)
Nm
32 38 51
1-1/4 1-1/2
-20 -24 -32
- - -
- - -
7/16-14 1/2-13 1/2-13
70
105 105
2
VII
Made with FlippingBook - Online Brochure Maker