Polymer Hose Distribution Catalogue 4402
Technical handbook
The correct method to fit ISO 6162-2 flange
The correct method to fit ISO 6162-2 flange
• Make sure sealing surfaces are free of burrs, nicks, scratches or any contamination • Lubricate the O-ring
• Position flange and clamp halves • Place lock washers on bolts and bolt through clamp halves
• Hand tighten bolts • Torque bolts in
• Tighten bolts according to chart
diagonal sequence in small increments to the appropriate torque level listed in chart
with system fluid or compatible lubricant
Spanner torque values
ISO 6162-2 flange
Assembly torque Tolerances: max. 10%; min. 0%
Assembly torque Tolerances: max. 10%; min. 0%
G Thread
G Thread
DN
Inch
Size
metric
Nm
UNC (Inch)
Nm
13 19 25 32 32 38 51 64 76
1/2 3/4
-8
M8x1.25 M10x1.5 M12x1.75 M12x1.75
24 50 92
5/16-18 3/8-16 7/16-14 1/2-13
24 43 70
-12 -16 -20 -20 -24 -32 -40 -48
1
1-1/4 1-1/4 1-1/2
130 150
105
M14x2 M16x2
-
-
210.0 400.0 600.0 650.0
5/8-11 3/4-10
210 360
2
M20x2.5
2-1/2
M24x3
- -
- -
3
M30x3.5
ISO 6162-2 flange 8000 psi
Assembly torque Tolerances: max. 10%; min. 0%
Assembly torque Tolerances: max. 10%; min. 0%
G Thread
G Thread
DN
Inch
Size
metric
Nm
UNC (Inch)
Nm
19 25 32 32
3/4
-12 -16 -20 -20
M10x1.5 M12x1.75 M12x1.75
60 92
3/8-16 7/16-14 1/2-13
- - - -
1
1-1/4 1-1/4
130 150
M14x2
-
VIII
Made with FlippingBook - Online Brochure Maker